Hall light only works sometimes
- Customer report
- The hall light only works sometimes. You have to flick both switches to get it to come on. The globe's been replaced and it's no different.
- Circuit
- Two-way lighting. Active goes to the common of SW1 (bottom of stairs). Two strappers run to SW2 (top of stairs), and SW2's common switches the active to the light. Up selects strapper 1, down selects strapper 2.
- Your job
- Find the fault with the fewest tests, working safely. The fault is different each time. Every test costs 2 points, unsafe steps cost more.
Circuit
Safety actions
Live tests are done energised with insulated probes and the right PPE. Dead tests need the circuit isolated, locked, tagged and proved dead.
Choose a test
Score
100Call the fault
Reviewer table
Pick a fault to see every reading the simulator shows for it. Chapter reference: [Jordan to add Bible chapter]
| Test | Condition | Reading | What it tells you |
|---|